Similar Posts
SA-35 Steam Atomizing Desuperheater
DESCRIPTIONThe Copes-Vulcan SA-35 Steam Atomizing Desuperheater is used to reduce the temperature of vapors such as steam with condensate such as water. It was developed to obtain a more uniform spray under varying load conditions where no pressure drop in the steam header can be tolerated. This desuperheater is made in four sizes, in pressure classes…
MA-III & MA-IIIU Mechanical Atomizing Desuperheater
DESCRIPTIONThe MA-III/MA-IIIU is a multi nozzle mechanical atomizing desuperheater that reduces steam or gas temperatures by introducing cooling liquids directly into the hot fluid. The MA-III/MAIIIU is a probe style direct contact heat exchanger. The liquid passes through the main tube of the desuperheater to the spray nozzles and discharges into the steam header. The MA-III/MA-IIIU…
MA-I / MA-IU Mechanical Atomizing Desuperheaters
DESCRIPTIONThe Copes-Vulcan MA-I/MA-IU Mechanical Desuperheater is generally used for attemporating applications featuring steady loads. It is particularly designed for rugged service and can maintain final temperature to within 20°F (11°C) of saturation. Maximum cooling liquid capacity is 25,860 lbs/hr (11,700 kg/hr) at a nozzle differential pressure of 160 psi (1100 kPa) when using 100°F (38°C)…
Multiple Nozzle Spray Desuperheater (MNSD)
DESCRIPTIONThe Copes-Vulcan Multiple Nozzle Spray Desuperheater offers optimum performance and rangeability in a variable spray tube design. The MNSD fills the performance gap between the limited capability of a simple mechanical spray type desuperheater and the virtually unlimited capability of Copes-Vulcan’s Variable Orifice Desuperheater. The MNSD offers high temperature capabilities and up to Class V…
Spring Assisted Multiple Nozzle Spray Desuperheater (SAMN-U)
DESCRIPTIONThe spring assisted multiple nozzle desuperheater reduces steam or gas temperatures by introducing cooling liquids directly into the hot vapor.Copes-Vulcan’s SAMN-U has six nozzles which can be opened or closed to vary the coolant flow. This provides a higher turndown than single nozzle units where the amount of coolant flow is dependent only on the…
MA-II / MA-IIU Mechanical Atomizing Desuperheaters
DESCRIPTIONThe Copes-Vulcan MA-II/MA-IIU is a mechanical atomizing desuperheater that is generally used for applications which feature steady loads. It is particularly designed for rugged service and can maintain final temperature to within 20°F (11°C) of saturation. In addition to steady load service, it is often used for attemporating applications, and performs equally well for both….